State Ohm's Law and name where it does NOT hold.
Ohm's Law says V = I * R. The voltage across a linear conductor is proportional to the current through it, as long as temperature stays the same. It does not hold for non-ohmic devices like diodes, transistors, and filament lamps, whose resistance changes with voltage or current. A lamp filament's resistance rises as it heats up. Mention that linearity assumption in your answer.
Companies known to ask: screener at nearly all EE employers
Explain Kirchhoff's Voltage Law (KVL) and Current Law (KCL).
KVL: the algebraic sum of all voltages around any closed loop is zero (conservation of energy). KCL: the algebraic sum of currents entering and leaving a node is zero (conservation of charge). Together they're the basis of mesh analysis (KVL per loop) and nodal analysis (KCL per node). Bonus points for citing a real use, e.g., verifying cell voltages in a series battery pack.
Companies known to ask: screener at nearly all EE employers
What's the difference between AC and DC, and why is AC used for the grid?
DC flows in one constant direction; AC reverses direction periodically (sinusoidal). AC is used for power delivery because it transforms easily between voltage levels via transformers, enabling efficient high-voltage long-distance transmission and low-voltage safe use. DC dominates in electronics and batteries. Modern HVDC is an exception for very long links.
Companies known to ask: utility, general EE
How do a capacitor and an inductor store energy, and how do they behave in a circuit?
A capacitor stores energy in an electric field between plates; voltage can't change instantaneously across it, so it blocks DC (open at steady state) and passes AC. An inductor stores energy in a magnetic field; current can't change instantaneously through it, so it passes DC (short at steady state) and opposes AC. Both are passive components, they store or dissipate energy but can't generate or amplify it.
Companies known to ask: general EE, hardware roles
What is impedance and how does it differ from resistance?
Impedance (Z) is the AC equivalent of resistance, measured in ohms, but it's a complex quantity combining resistance (real part) and reactance (imaginary part) from capacitors and inductors. It captures both the magnitude of opposition to current and the phase shift between voltage and current. Pure resistance has no phase shift; reactance does. Phasors represent these sinusoids as complex numbers at one frequency.
Companies known to ask: general EE, power roles
Define power factor and explain why low power factor is a problem.
Power factor = real power (kW) / apparent power (kVA) = cos(theta), where theta is the phase angle between voltage and current. A low PF means more current is needed to deliver the same real power, causing higher I^2R losses, voltage drops, and larger conductor/equipment sizing, and utilities often bill industrial customers penalties for it. PF correction (usually capacitor banks) offsets inductive load and raises PF.
Companies known to ask: utility, industrial EE
Contrast single-phase and three-phase systems.
Single-phase uses one AC voltage (live + neutral), common in residential loads. Three-phase uses three AC voltages 120 degrees apart, standard in industry because it delivers constant (non-pulsating) power, needs less conductor material for the same power, and runs motors more efficiently. Line voltage is phase-to-phase; phase voltage is phase-to-neutral (line = sqrt(3) x phase for a wye system).
Companies known to ask: utility, industrial EE
What is a transformer and how does it work?
A transformer transfers energy between two magnetically coupled coils via a changing magnetic flux (Faraday's law), no direct electrical connection. The voltage ratio equals the turns ratio (Vp/Vs = Np/Ns), and power is conserved (ideal), so stepping voltage up steps current down. It only works on AC because it needs changing flux. It's the reason AC transmission is practical.
Companies known to ask: utility, T&D
Difference between active and passive components? Conductor vs. insulator?
Passive components store or dissipate energy but can't amplify or generate it (resistors, capacitors, inductors); active components need an external source and can amplify/control signals (transistors, op-amps, diodes in some contexts). Conductors have low resistance and allow easy current flow (copper, aluminum); insulators have very high resistance and resist it (rubber, glass, plastic). Semiconductors sit in between and are controllable via doping.
Companies known to ask: general EE screener
What is Thevenin's theorem and when is it useful?
Thevenin's theorem says any linear two-terminal network can be reduced to a single voltage source (Vth, the open-circuit voltage) in series with a single resistance (Rth, the resistance seen from the terminals with sources zeroed). It's useful for analyzing how different loads behave on the same network without re-solving the whole circuit each time, e.g., maximum power transfer and load analysis. Norton's is its current-source dual.
Companies known to ask: general EE, hardware roles
What's the difference between earthing (grounding) for safety vs. system grounding?
Protective earthing connects exposed metal parts to earth so a fault trips protection and doesn't leave equipment live, it protects people from shock. System grounding connects the system neutral/reference to earth to stabilize voltages relative to ground and provide a defined return path for fault current so protection can detect and clear faults. Same word, two distinct jobs, call out both.
Companies known to ask: utility, field EE
What's the difference between current and voltage?
Current is the flow of electric charge through a conductor, measured in amperes (A). Voltage is the potential difference (the 'push') between two points, measured in volts (V). Current is the quantity of charge flowing; voltage is the force driving it. The water analogy: voltage is pressure, current is flow rate, resistance is pipe restriction.
Companies known to ask: general EE screener
What does a diode do?
A diode is a two-terminal semiconductor (anode, cathode) that allows current in only one direction, forward-biased it conducts, reverse-biased it blocks. Uses: rectification (AC to DC), reverse-polarity protection, and voltage clamping/regulation (Zener). It's the simplest nonlinear device and a very common screener question.
Companies known to ask: general EE, hardware roles
How does a transistor work, and how is it used as a switch?
A transistor is a three-terminal semiconductor that amplifies or switches signals. In a BJT, a small base current controls a larger collector-emitter current. In a MOSFET, a gate voltage controls the channel. When it's used as a switch, it's driven between cutoff (fully off) and saturation (fully on). That on/off behavior is the basis of all digital logic and power switching.
Companies known to ask: general EE, hardware roles
What's the difference between a BJT and a FET?
A BJT (bipolar junction transistor) is current-controlled and bipolar (both electrons and holes conduct), with lower input impedance. A FET (field-effect transistor) is voltage-controlled and unipolar (majority carriers only), with very high input impedance. FETs draw negligible gate current and dominate in digital/low-power design; BJTs offer high transconductance for some analog uses.
Companies known to ask: hardware, analog roles
What are the properties of an ideal op-amp?
Infinite open-loop gain, infinite input impedance (no input current), zero output impedance, infinite bandwidth, and zero offset. With negative feedback, the two 'golden rules' follow: no current flows into the inputs, and the inputs are driven to the same voltage (virtual short). These let you analyze inverting, non-inverting, and summing configurations quickly.
Companies known to ask: analog, hardware roles
What is a transistor?
A transistor is a three-terminal semiconductor device that acts as an electronically controlled switch or amplifier: a small signal at one terminal controls a much larger current or voltage between the other two. It's the fundamental building block of essentially all modern electronics, from logic gates to power stages. The two main families are the BJT (current-controlled) and the FET/MOSFET (voltage-controlled).
Companies known to ask: general EE, hardware roles
What are the three terminals of a BJT?
The base, the collector, and the emitter. The base is the control terminal: a small base current controls the much larger current flowing from collector to emitter (in an NPN). Current gain beta = Ic/Ib. The emitter is where carriers originate, the collector is where they are collected, and the base modulates the flow between them.
Companies known to ask: general EE, analog roles
What is RMS value and why do we use it for AC?
RMS (root-mean-square) is the equivalent DC value that delivers the same average power to a resistive load. For a sine wave, Vrms = Vpeak/sqrt(2) (~0.707*Vpeak). We use RMS because AC voltage/current continuously vary, and RMS gives the meaningful 'effective' value for power calculations. Mains rated '120 V' or '230 V' is an RMS figure.
Companies known to ask: general EE, power roles
What's the difference between real, reactive, and apparent power?
Real power (P, watts) does useful work. Reactive power (Q, VAR) shuttles energy back and forth in inductors/capacitors and does no net work. Apparent power (S, VA) is the vector sum, S = sqrt(P^2 + Q^2), and equals V*I. The power triangle relates them; power factor is cos of the angle between S and P. Utilities size equipment for apparent power.
Companies known to ask: utility, power roles
Compare series and parallel circuits.
In series, components share one path, so the same current flows through each and voltages add; one break stops everything (old holiday lights). In parallel, components share the same voltage and currents add; each branch is independent (household outlets). Series resistances add directly; parallel resistances combine as reciprocals.
Companies known to ask: general EE screener
How do you use nodal and mesh analysis?
Nodal analysis applies KCL at each node to solve for node voltages, efficient when there are fewer nodes. Mesh analysis applies KVL around each independent loop to solve for loop currents, efficient when there are fewer loops. Both are systematic ways to solve circuits too complex for simple series/parallel reduction; pick whichever yields fewer equations.
Companies known to ask: general EE, circuits roles
Explain a PID control loop and what each term does.
PID = Proportional-Integral-Derivative. It's a closed-loop feedback controller that drives the error between the setpoint and process variable toward zero. Proportional reacts to present error (bigger error -> bigger correction), Integral accumulates past error to eliminate steady-state offset, and Derivative reacts to the rate of change to dampen overshoot. Tuning the three gains balances overshoot, settling time, and steady-state error.
Companies known to ask: Enterprise Automation, Tesla, Rockwell, integrators
What's the difference between a PLC and a DCS, and when would you use each?
A PLC (Programmable Logic Controller) is a ruggedized industrial computer optimized for fast, discrete/sequential logic and machine control. A DCS (Distributed Control System) uses multiple autonomous controllers distributed across a large process and is optimized for continuous analog control, plant-wide coordination, and redundancy. Use a PLC for discrete manufacturing/machine automation; use a DCS for large continuous processes (refining, power, chemical) where many loops must be coordinated with high availability.
Companies known to ask: Enterprise Automation, oil & gas, manufacturing
Name the five IEC 61131-3 programming languages.
Ladder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), Instruction List (IL), and Sequential Function Chart (SFC). Ladder is most common for discrete logic; Structured Text suits math and complex algorithms; SFC organizes step-based sequences.
Companies known to ask: Rockwell, Siemens integrators
What's the difference between a Function Block (FB) and a Function (FC)?
An FB has an associated instance data block that retains state between scan cycles, so it's used for anything needing memory: timers, counters, PID controllers, motor-control objects. An FC is stateless and appropriate for calculations that don't need memory: unit conversions, alarm-limit checks, math operations.
Companies known to ask: Siemens, automation integrators
A pressure transmitter outputs 4-20 mA. How does the PLC turn that into engineering units?
The 4-20 mA analog signal is read by the analog input module and converted to a raw integer (e.g., 0-32767 for a 15-bit module). The program then linearly scales that raw count to engineering units using the sensor's range: EU = min + (raw - raw_min)/(raw_max - raw_min) * (max - min). 4 mA maps to the low end of the range, 20 mA to the high end.
Companies known to ask: process/manufacturing employers
Describe how you'd implement a control system to transfer a gas (e.g., oxygen) from one tank to another.
Frame it as a closed loop: define the controlled variable (destination pressure or mass), measure it with a pressure/flow transmitter, and modulate a control valve via a PID (or on/off) controller to hit the setpoint. Add interlocks and alarms for over-pressure, sequencing to open/close valves in a safe order, and consider flow vs. pressure control depending on the goal. Discuss instrumentation, actuator selection, and safety trips.
Companies known to ask: Enterprise Automation, process employers
Draw a passive RC low-pass filter and characterize it.
Sketch: the input goes through a series resistor R to the output node, and a capacitor C runs from that output node to ground; the output is taken across the cap. At low frequency the cap is high impedance (open), so the output follows the input (passes). At high frequency the cap is low impedance (short to ground), so the output is attenuated (blocked). Cutoff (-3 dB) frequency: fc = 1/(2*pi*R*C). Above fc the gain rolls off at -20 dB/decade (first order). It passes lows and rejects highs.
Companies known to ask: analog, hardware, general EE
Draw a non-inverting op-amp amplifier and characterize it.
Sketch: the input signal goes to the op-amp's non-inverting (+) input; a feedback resistor Rf connects the output back to the inverting (-) input, and a resistor Rg runs from that (-) input to ground. By the virtual-short rule, the closed-loop gain is Av = 1 + Rf/Rg. Key traits: gain is always >= 1 (it can't attenuate), the output is in phase with the input (non-inverting), and it has very high input impedance, so it's great for buffering. With Rf = 0 (or Rg open) it becomes a unity-gain buffer.
Companies known to ask: analog, hardware, general EE
Combine the RC low-pass filter and the non-inverting amp into an active low-pass filter. Write the gain at low and high frequency.
Put the RC low-pass filter on the non-inverting input. R goes in series from the source, and C goes from the + input to ground. Then build the non-inverting amplifier around it, with Rf from the output to the - input and Rg from the - input to ground. The op-amp adds gain and buffers the filter so later stages don't load it. At low frequency the cap is open, the full signal reaches the + input, and the gain is the passband gain Av = 1 + Rf/Rg. At high frequency the cap shorts the + input to ground, so the output drops toward zero. The cutoff is still fc = 1/(2*pi*R*C). The advantage over a passive filter is that the passband gets amplified and buffered.
Companies known to ask: analog, hardware, general EE
Draw a buck converter and explain how it steps voltage down.
A buck converter uses a switch (MOSFET), a diode (or synchronous switch), an inductor, and an output capacitor. When the switch is on, current ramps up in the inductor and delivers energy to the load; when off, the inductor maintains current through the diode. Duty cycle D sets the ratio: Vout = D * Vin (ideal, continuous conduction). PWM control of D regulates the output.
Companies known to ask: Tesla, Apple, Texas Instruments, Nvidia
How do you choose between a MOSFET and an IGBT?
Rule of thumb: MOSFETs for high switching frequency (roughly >200 kHz) and lower voltages, because they switch fast with low switching loss. IGBTs for high-voltage, higher-power, medium-frequency applications (inverters, motor drives) where they combine MOSFET-like gate drive with low conduction loss. IGBTs have higher switching losses, so they're weaker at very high frequency.
Companies known to ask: Tesla, power supply firms
What parameters do you check on a MOSFET datasheet for a switching design?
Drain-to-source voltage (VDSS) for margin, on-resistance RDS(on) for conduction loss, gate charge QG for drive requirements and switching speed, reverse-recovery charge/current of the body diode, and thermal characteristics (junction temp, Rth). Low RDS(on) cuts conduction loss; low QG allows faster, more efficient switching.
Companies known to ask: power electronics employers
What are the main loss mechanisms in a switching converter?
Conduction losses (voltage drop across the switch while on), switching losses (energy dissipated during turn-on/turn-off transitions), and leakage losses (reverse leakage when off). Additional real-world losses: gate-drive loss, magnetic core/copper loss, and EMI-related. Reducing them means picking the right device, optimizing switching frequency, and good thermal/layout design.
Companies known to ask: SMPS/hardware employers
To get 12V out, is a 48V or 24V input better for the converter? Why?
For a buck converter, lower input voltage (24V) gives a higher duty cycle to reach 12V, meaning the switch conducts a larger fraction of each cycle. Higher input (48V) means smaller duty cycle. The 'better' choice depends on the tradeoff: higher Vin lowers input current (good for wiring/conduction loss) but stresses the switch with higher voltage and can hurt efficiency at very small duty cycles. Discuss the tradeoff rather than a single answer.
Companies known to ask: power supply design roles
What is MPPT and why does a solar system need it?
MPPT = Maximum Power Point Tracking. A PV panel's power output is a nonlinear function of voltage/current that shifts with irradiance and temperature. MPPT continuously adjusts the operating voltage/current to sit at the maximum-power point, extracting the most available energy. It's implemented in the inverter/charge controller.
Companies known to ask: solar developers, inverter firms
How do you size PV strings, and what's the difference between a string and an array?
You size series strings so the array voltage stays within safe limits across temperature extremes (cold raises panel voltage), keeping the inverter in its optimal MPPT window, then parallel multiple strings to reach the target capacity. A string is panels wired in series (adds voltage); an array is multiple strings combined (parallel adds current). Design must stay code-compliant and serviceable.
Companies known to ask: solar EPC, design roles
What factors affect wind turbine efficiency?
Wind speed (output rises steeply with speed), turbine/blade design (length, shape, pitch, orientation), rotor size, altitude and air density, turbulence and wind shear, and maintenance. Offshore sites often see higher, steadier wind. Discuss the Betz limit (~59.3% theoretical max) if pushed further.
Companies known to ask: wind developers, OEMs
What is curtailment and why does it matter to project economics?
Curtailment is when a renewable plant's output is deliberately cut below what it could produce. It usually happens because of grid congestion, export limits, or too much supply. It directly cuts the energy (MWh) the plant can sell, so it's a major economic risk. You estimate it by modeling export limits and congestion patterns, then turning the lost MWh into lost revenue.
Companies known to ask: developer/analyst roles
What interconnection requirements apply to inverter-based resources?
Grid codes require voltage and frequency ride-through, reactive power capability, and defined protection/control settings so the resource supports rather than destabilizes the grid. Grid-forming inverters can provide stability in low-inertia systems. Compliance testing is part of commissioning.
Companies known to ask: utility, grid integration roles
What does the 'volatile' keyword do and when is it required?
volatile tells the compiler a variable's value may change outside the program's control, so it must not optimize away reads/writes and must always fetch from memory. Required for memory-mapped hardware registers, variables shared with an ISR, and flags modified by other threads. Omitting it can cause the compiler to cache a stale value and the program to miss hardware/ISR updates.
Companies known to ask: Google, Amazon, Nvidia, Apple
How do you convert a hexadecimal number to binary?
Each hex digit maps directly to exactly 4 binary bits, so you convert one digit at a time and concatenate. For example 0x2F: 2 = 0010 and F = 1111, giving 0010 1111. Going the other way, group the binary into nibbles of 4 (from the right) and convert each to its hex digit. This 1-hex-digit-to-4-bits shortcut is why hex is used as shorthand for binary in registers and memory addresses.
Companies known to ask: Google, Amazon, Nvidia, embedded roles
Write a function to set bits 3-5 of a 16-bit register to a value without touching other bits.
Mask out the target field, then OR in the shifted value. Example: reg = (reg & ~(0x7 << 3)) | ((value & 0x7) << 3). The AND with the inverted 3-bit mask clears bits 3-5; the OR writes the new masked value shifted into position. Using bitwise ops preserves the other bits.
Companies known to ask: Google, Amazon, Nvidia
How do you implement a single-producer/single-consumer ring buffer, and why must head/tail be volatile?
Use a fixed array with head and tail indices; producer writes at head then advances, consumer reads at tail then advances, both modulo buffer size, with a full/empty check. head and tail must be volatile because one is updated in the ISR and the other in main context, so the compiler must not cache them. This pattern appears in almost every UART driver.
Companies known to ask: Google, Amazon embedded
Explain interrupt handling best practices for ISRs.
Keep ISRs short and fast, avoid blocking calls and long processing, defer heavy work to the main loop via flags or queues, and use volatile for shared variables. Understand nesting/priority so higher-priority interrupts can preempt lower ones, and watch stack usage to avoid overflow. Distinguish hardware interrupts (external events) from software interrupts (code-triggered).
Companies known to ask: embedded employers broadly
How do you prevent priority inversion in an RTOS?
Priority inversion happens when a high-priority task waits on a mutex held by a low-priority task that gets preempted by a medium-priority task. Fix it with priority inheritance (the low-priority holder temporarily inherits the waiter's priority) or priority ceiling protocol (the mutex runs at a defined ceiling priority). Many RTOS mutexes offer inheritance as an option.
Companies known to ask: Amazon (FreeRTOS), Nvidia
Describe the memory layout of a C program.
Segments: text (code, read-only), initialized data (.data), uninitialized data (.bss, zeroed at startup), the heap (dynamic allocation, grows up), and the stack (local variables/call frames, grows down). Globals/statics live in .data or .bss; locals live on the stack; malloc'd memory lives on the heap. Knowing this explains crashes like stack overflow and helps constrained-memory design.
Companies known to ask: Google, Nvidia embedded
Explain how electricity is generated and then ends up in your home.
At the power plant, a prime mover (steam from coal/gas/nuclear, or water/wind) spins a turbine coupled to a synchronous generator, which produces three-phase AC by electromagnetic induction, typically at around 11 to 25 kV. A step-up transformer raises it to high transmission voltage (roughly 138 to 765 kV) so it can travel long distances with low I-squared-R losses. At substations, step-down transformers reduce it to distribution voltage (e.g., 4 to 35 kV) that runs along neighborhood lines. A final distribution transformer (the can on the pole or the pad-mount box) steps it down to 120/240 V, which enters your home through the service drop, meter, and panel to your outlets. Solar and other DER can also inject power at the distribution edge, making flow two-directional.
Companies known to ask: utility, general EE
Give the torque and speed equations for a DC motor.
Back-EMF: E = k*phi*omega. Torque: T = k*phi*Ia (torque proportional to armature current and flux). Terminal relation: V = E + Ia*Ra. Speed: omega = (V - Ia*Ra)/(k*phi), so speed rises with applied voltage and falls with armature-resistance drop; weakening flux raises speed. Be ready to sketch the torque-speed curve.
Companies known to ask: utility, motor/drive employers
How does excitation affect a synchronous generator's output?
Excitation controls field current and therefore the machine's internal EMF. Over-excitation makes the generator supply reactive power (lagging, acts capacitive to the grid) and raises terminal voltage; under-excitation absorbs reactive power. Real power is set by the prime mover/torque, while excitation sets reactive power and voltage. This is the basis of AVR operation.
Companies known to ask: utility, generation employers
Compare HVDC and HVAC transmission.
HVDC transmits DC: lower losses over long distances, no reactive charging current, allows asynchronous grid ties, and needs fewer conductors, but converter stations are expensive. HVAC allows easy voltage transformation and is standard for shorter distances and networked grids. HVDC wins for very long lines, submarine cables, and interconnecting asynchronous systems.
Companies known to ask: utility, T&D employers
What is the per-unit system and why is it used?
Per-unit expresses quantities as a ratio to chosen base values (per-unit = actual/base). Choosing a common power base and voltage base puts the whole system on one scale, so transformers' turns ratios disappear, values are easy to compare across voltage levels, and fault/load-flow calculations simplify. You pick a 3-phase power base and line-to-line voltage base, then derive current and impedance bases.
Companies known to ask: utility & consultants
How do you calculate short-circuit / fault current?
For a simple case, fault current = pre-fault voltage / impedance to the fault (I = V/Z) in per-unit. For unbalanced faults, use symmetrical components: build positive-, negative-, and zero-sequence networks and connect them per the fault type (L-G, L-L, L-L-G, 3-phase). The fault magnitude sets protection settings and equipment interrupting ratings.
Companies known to ask: utility, protection engineering
Name the fault types and which are symmetrical vs. unsymmetrical.
Three-phase (and three-phase-to-ground) faults are symmetrical/balanced (all phases equal). Line-to-ground (L-G), line-to-line (L-L), and double-line-to-ground (L-L-G) are unsymmetrical. Single-line-to-ground is the most common in practice; the balanced three-phase fault is usually the most severe for interrupting rating.
Companies known to ask: utility, T&D employers
What's the difference between a relay and a circuit breaker, and what does a protective relay do?
A protective relay detects abnormal conditions (over-current, under-voltage, etc.) and sends a trip signal; the circuit breaker is the high-current interrupting device that physically disconnects the faulted section. The relay is the brains, the breaker is the muscle. Protection coordination sets relay pickups and timing so the closest device clears the fault first, minimizing outage scope.
Companies known to ask: utility, protection roles
What is load-flow (power-flow) analysis and why is it run?
Load flow solves for the steady-state voltage magnitude/angle at every bus and the real/reactive power flows and losses across the network. It's used to verify voltages stay in range, identify overloads and voltage drops, plan upgrades, and study future expansion. It's foundational for distribution planning.
Companies known to ask: utility distribution planning
How do distributed energy resources (DER) change protection and planning?
DER (rooftop solar, storage, EVs) inject power at the distribution edge, so power can flow bidirectionally instead of one-way from substation to load. That complicates protection coordination (fault current from multiple sources), voltage regulation (reverse flow raises voltage), and hosting-capacity planning. Advanced inverter settings, updated relay schemes, and load/DER forecasting are used to manage it.
Companies known to ask: utility, grid modernization
How do battery storage and hybridization improve renewable project value?
Storage firms up variable output, shifts energy to high-value periods, provides grid services (frequency, reserves), and lets co-located solar+storage or wind+storage share interconnection capacity, improving utilization and managing congestion. This changes project economics and market participation versus a standalone renewable plant.
Companies known to ask: developer, utility roles
How does improved load forecasting help grid operations?
Better forecasts (including weather-to-power and AI-driven models) improve dispatch planning, reduce imbalance/reserve costs, and support hosting-capacity and infrastructure decisions. Granular hourly forecasting informs where and when the grid needs reinforcement or DER management.
Companies known to ask: utility, ISO/RTO
What is setup time and hold time?
Setup time is the minimum time before a clock edge that the data input must be stable so the flip-flop reliably captures it. Hold time is the minimum time after the clock edge that the data must stay stable. Violating either causes the flop to capture wrong data or go metastable. They bound how fast you can clock a design and are the core of static timing analysis (STA).
Companies known to ask: Nvidia, Intel, AMD, Qualcomm, Apple
Compare ASIC and FPGA. When would you choose each?
An ASIC is a custom-fabricated chip optimized for performance, power, and area (PPA), but with high upfront (NRE) cost and long lead time, so it suits high-volume production. An FPGA is a reprogrammable device offering flexibility and fast time-to-market at higher per-unit cost, power, and lower peak performance, so it suits prototyping, low volume, and evolving designs. The tradeoff is NRE/volume vs. flexibility.
Companies known to ask: chip design firms
Walk me through the ASIC design flow from RTL to tape-out.
RTL design in Verilog or VHDL. Functional simulation and verification. Synthesis, which turns RTL into a gate-level netlist under timing constraints. DFT insertion, like scan chains and BIST, for testability. Then floorplanning, placement, clock tree synthesis, routing, static timing analysis, and physical verification (DRC and LVS). Then tape-out and fabrication. Name the steps from frontend to backend and say what each one does.
Companies known to ask: chip design firms
What is metastability and how do you deal with it?
Metastability is when a flip-flop's output hovers in an undefined state (neither valid 0 nor 1) because a data change violated its setup/hold window, often at an asynchronous clock domain crossing. It resolves unpredictably and can propagate bad data. Mitigation: a synchronizer, typically two (or more) flip-flops in series, gives the signal time to settle, trading a cycle of latency for a hugely improved mean-time-between-failure (MTBF).
Companies known to ask: chip design firms
What is clock domain crossing (CDC) and why is it a problem?
CDC is when a signal passes between two circuits running on unrelated (asynchronous) clocks. Because the receiving flop can sample the signal while it's changing, it risks metastability and data loss/corruption. You handle single-bit signals with multi-flop synchronizers and multi-bit buses with handshakes, gray-coded FIFOs, or async FIFOs so all bits transfer coherently. CDC bugs are a top cause of silicon failures.
Companies known to ask: chip design firms
What's the difference between a latch and a flip-flop?
A latch is level-sensitive: it's transparent (passes input to output) while its enable is active, and holds when inactive. A flip-flop is edge-sensitive: it captures the input only on a clock edge and holds otherwise. Flip-flops are the standard sequential element in synchronous design because edge-triggering gives predictable timing; latches can cause timing/analysis complications and are often flagged in synthesis.
Companies known to ask: chip design firms
What's the difference between blocking and non-blocking assignments in Verilog?
Blocking (=) executes sequentially in order, like software statements, and is used for combinational logic. Non-blocking (<=) schedules all right-hand sides to update together at the end of the time step, modeling parallel register updates, and is used for sequential (clocked) logic. The rule of thumb: non-blocking in clocked always-blocks, blocking in combinational ones. Mixing them causes race conditions and simulation-vs-synthesis mismatches.
Companies known to ask: chip design, verification roles
A setup timing violation shows up after synthesis. How do you debug it?
Read the timing report to confirm it's a setup (not hold) violation and find the worst path and its slack. Examine the path's start/end points, the combinational logic depth, and the cells between them. Fixes: reduce logic depth (restructure or pipeline), upsize/ swap to faster cells, adjust the clock (lower frequency or fix skew), or add retiming. State that you'd attack the critical path's excess delay methodically, that reasoning is the signal.
Companies known to ask: chip design, physical design roles
What is expected value and why does it matter in trading?
Expected value (EV) is the probability-weighted average of all outcomes. EV = sum(probability * value). Trading is repeated decision-making under uncertainty, so you take positions with positive EV and size them by risk. A trade can lose often and still be +EV if the wins are big enough. This question checks whether you think in probabilities and payoffs instead of single outcomes.
Companies known to ask: Jane Street, Citadel, Optiver, SIG, Jump
What is arbitrage and what does 'no-arbitrage' mean?
Arbitrage is a risk-free profit from price discrepancies, buying and selling equivalent assets at different prices for a guaranteed gain. 'No-arbitrage' is the assumption that such free money doesn't persist because traders instantly exploit it away. It's the foundation of derivatives pricing: a fair price is the one that admits no arbitrage (e.g., put-call parity). If you can construct an arbitrage, the prices are wrong.
Companies known to ask: quant research, trading firms
You flip a fair coin until it lands heads. What's the expected number of flips?
2. Set up the recursion. Let E be the expected number of flips. Half the time you get heads on the first flip, which takes 1 flip. The other half you get tails and start over, which takes 1 + E. So E = 1 + (1/2)E, and E = 2. For a coin with heads probability p, the expected number of flips is 1/p (the geometric distribution). Show the recursion. That's the part they're grading.
Companies known to ask: Jane Street, Optiver, SIG, Citadel
You have 100 coins: 99 fair, 1 double-headed. You pick one at random and flip 10 heads in a row. What's the probability it's the double-headed coin?
About 91%. Use Bayes' theorem. P(2-headed | 10H) = P(10H | 2-headed) * P(2-headed) / P(10H). The numerator is 1 * 0.01 = 0.01. The fair coin adds (1/1024) * 0.99 ≈ 0.000967. So P = 0.01 / (0.01 + 0.000967) ≈ 0.912. Ten heads in a row is strong evidence, so it moves a small prior a lot. Set up Bayes cleanly and the math follows.
Companies known to ask: Jane Street, Citadel, SIG
What is the Central Limit Theorem and why does it matter?
The CLT says the sum (or average) of many independent, identically distributed random variables approaches a normal distribution as the sample size grows, regardless of the original distribution (given finite variance). It matters because it justifies using the normal distribution for aggregated quantities (like average returns or estimation errors) and underlies confidence intervals and hypothesis testing. It's why 'bell curves' show up everywhere.
Companies known to ask: quant research, data roles
What is the difference between a call and a put option?
A call gives the holder the right (not obligation) to BUY the underlying at the strike price by expiry; you buy calls when you expect the price to rise. A put gives the right to SELL at the strike; you buy puts when you expect the price to fall or want downside protection. The buyer pays a premium; the seller (writer) collects it and takes on the obligation. It's the foundational options question.
Companies known to ask: quant, options trading firms
Explain put-call parity.
For European options on a stock with no dividend, C - P = S - K*e^(-rt). C and P are the call and put prices at the same strike K and expiry, S is the spot price, and r is the risk-free rate. It says a call minus a put equals a forward position in the stock. It's an arbitrage relationship. If it breaks, you can lock in a risk-free profit, so it has to hold. It also lets you price one option from the other.
Companies known to ask: options trading firms, quant
What are the option Greeks (delta, gamma, theta, vega)?
They measure an option's price sensitivity. Delta: change in option price per $1 move in the underlying (also the hedge ratio). Gamma: rate of change of delta (curvature). Theta: time decay, how much value is lost per day. Vega: sensitivity to implied volatility. Traders hedge delta and manage gamma/vega exposure. Knowing what each measures, and their signs for long options, is essential.
Companies known to ask: options trading firms
What is the intuition behind the Black-Scholes model?
Black-Scholes prices a European option by assuming the underlying follows geometric Brownian motion. The key insight: you can build a risk-free portfolio by continuously delta-hedging the option with the underlying, which (by no-arbitrage) must earn the risk-free rate. That leads to the Black-Scholes PDE and a closed-form price depending on spot, strike, time, rate, and volatility. Volatility is the only unobservable input, which is why the market trades on implied vol.
Companies known to ask: options trading, quant research
"Make me a market": I'll pay you the number of flips to get the first head. What do you quote?
The expected payoff is 2 (expected flips to first head with a fair coin). A reasonable two-sided market is bid 1.5, ask 2.5, buying below fair value and selling above it, capturing a spread around EV. Note the distribution has a long right tail (rare large payoffs), so you might skew slightly. And critically: if the interviewer keeps trading one side, they may have information, so you adjust your quotes. Show EV plus the market-making logic.
Companies known to ask: Optiver, IMC, SIG, Jane Street
What is the bid-ask spread and what does it represent?
The bid is the highest price buyers will pay; the ask is the lowest price sellers will accept; the spread is the difference. It represents the cost of immediacy and compensates market makers for providing liquidity and bearing inventory/adverse-selection risk. Tighter spreads mean more liquid markets. As a trader you cross the spread to trade immediately or post inside it to earn it.
Companies known to ask: trading firms
What is a Monte Carlo simulation and when would you use it in finance?
Monte Carlo estimates a quantity by simulating many random scenarios and averaging the results. In finance you use it to price complex/path-dependent derivatives (where no closed form exists), to estimate portfolio risk (VaR), and to model uncertain cash flows. Accuracy improves with the square root of the number of simulations, so it's flexible but can be compute-heavy; variance-reduction techniques help.
Companies known to ask: quant research, quant dev